ESCRS - PP09.12 - Long Term Results Of Punchorhexis In White Intumescent Cataract

Long Term Results Of Punchorhexis In White Intumescent Cataract

Published 2026 - 44th Congress of the ESCRS

Reference: PP09.12 | Type: Free paper | DOI: 10.82333/j5kw-b109

Authors: Prof. Dr Mohan Rajan* 1 , Dr Sujatha Mohan 2

1Retina,Rajan Eye Care Hospital Pvt Ltd,Chennai,India, 2Cornea,Rajan Eye Care Hospital Pvt Ltd,Chennai,India

Purpose

To prevent argentina flag sign in white intumescent cataracts

Setting

Rajan Eye Care Hospital Pvt Ltd, Chennai

Methods

510 eyes of 510 patients with white intumescent cataract were taken up for this study. Trephine blue was used to stain the anterior capsule. The punchorhexis was done using a straight 15 degree phaco tip bevel down using 40% phaco power, 350-400mm Hg vacuum on the stellaris phaco machine. Once a punch was made the rhexis was completed either with the phaco needle itself (phaco rhexis) or with uttrata forceps.

Results

In all eyes except 2 eyes the punchorhexis was successful.

Conclusions

Punchorhexis is an effective method of achieving good rhexis in white intumescent cataract there by preventing argentina flag sign.