My Experience With The Panoptix Toric Intraocular Lens
Published 2026 - 44th Congress of the ESCRS
Reference: POCAT517 | Type: Free paper | DOI: 10.82333/y3pr-ss93
Authors: Dr Nandini Ray* 1
1Eye,Radiant Eye Foundation ,Kolkata ,India
Purpose
With my experience over 36 months with 164 eyes implanted with Panoptix multifocal ( mIOL) and 200 eyes implanted with Alcon TORIC IOL , I decided tp implant Panoptix Toric for patients with borderline astigmatism wanting spectacle freedom and to judge the overall initial efficacy
Setting
Single centre, single surgeon, retrospective analysis . Centurion phaco machine ,Lenstar Biometry ( 2 technician) General Ophthalmology Clinic
No access to Verion /Callisto/ Pentacam /Wavefront Aberrometer/ Image Guided Cataract surgery suite
Methods
Strict patient selection as per multi focal IOL with routine surgery
Avoid patients with any ocular pathology
Avoid high myopes ( < 16D) uncertainty about the final ELP
Avoid high Astigmatism (>2 D) for the initial 30 eyes
Cross correlate with previous glasses / prescriptions
Post operative refraction done 1 week later
Results
Number of eyes 30/Bilateral implant 10 patients ( 20 eyes) /Unilateral 10 eyes
Male:Female 8:20/Age average 67.73 years
Phaco :Femto 16:14
Average K1/K2 difference 1.33 in PanToric
Average K1/ K2 difference in normal Toric 2.16
K1/K2 Panoptix difference 0.42( very low astigmatism)
Average IOL power in Panoptix Toric 23 D / Panoptix 22 D
Normal Toric
T3:11eyes & T4/T5 :89
T6T7:66 & T8/T9: 34
PanToric :T2 20/T3 10 eyes
Refractive Outcome
Panoptix Toric :24 eyes Plano 6/6, N6
6 eyes SE upto 0.25 D 6/6 p N6
Panoptix :Plano 144 eyes /SE 0.25D-0.5D 20 eyes
TORIC residual astigmatism :PLANO 80
0.25D-0.5D 71 eyes / 0.75D-1D 30eyes
1D-1.50D 17eyes/>1.5 D 2 eyes
Conclusions
In a general eye clinic with near basic equipment the surgeon has hand picked a careful limited section of patients who meet all the selection criteria
With a past experience in the TORIC IOL STUDY of 25% residual post operative astigmatism >0.5D the surgeon implanted only cases with upto T3 Panoptix Toric as our centre did not have advanced technology equipment
With good post operative results 6 eyes having maximum 0.25D SE
24 eyes strictly Plano 6/6, N6
So careful patient selection , methodical screening with exclusion and cross correlation with past prescriptions/ glasses etc patient satisfaction can be expected