ESCRS - POCAT509 - Identifying Factors On Scheimpflug Corneal Imaging That Predict Presbyopia-Correcting Intraocular Lens Intolerance

Identifying Factors On Scheimpflug Corneal Imaging That Predict Presbyopia-Correcting Intraocular Lens Intolerance

Published 2026 - 44th Congress of the ESCRS

Reference: POCAT509 | Type: Free paper | DOI: 10.82333/m4fn-sy11

Authors: Claudia Perez-Straziota* 1 , Dr Bianca Susanna 1 , Dr Molly Snider 1 , Dr Bassel Hammoud 1

1Ophthalmology ,Cole Eye Institute,Cleveland,United States

Purpose

To identify any features on preoperative Scheimpflug imaging that predispose patients to presbyopia-correcting intraocular lens (PrC-IOL) intolerance.

Setting

US Academic Institution

Methods

Retrospective review of all patients who had a presbyopia-correcting IOL (PrC-IOL) implant at the time of cataract surgery who had preoperative Scheimpflug imaging obtained with the Pentacam HR device.  Patients with PC-IOL intolerance were compared to those with successful outcomes.  Variables analyzed included multiple keratometry metrics, thinnest pachymetry, asymmetry indices, Q value, Corneal RMS values, and individual Zernike values.

Results

Out of an overall cohort comprising 505 patients with presbyopia-correcting lens implantation, 227 patients (44.9%) had preoperative Scheimpflug imaging performed.  The PC-IOLs implanted in this series included diffractive bifocal (bifocal, ReSTOR IOL, Alcon, Inc.), diffractive trifocal (trifocal, Panoptix IOL, Alcon, Inc.) diffractive extended depth of focus (EDOF, Tecnis Symfony, J&J), and non-diffractive extended depth of focus (N-EDOF, Vivity, Alcon, Inc.).  Among the cohort, 86% of patients were satisfied after PC-IOL implantation, while 14% were dissatisfied postoperatively.  There were no significant differences for any primary Scheimpflug variable evaluated between satisfied and dissatisfied groups (p>0.05 for all).

 

Conclusions

Basic Scheimpflug imaging parameters were not predictive of patient satisfaction following PrC-IOL implantation.