ESCRS - POCAT294 - The Spin-And-Flip Technique: A Standardized, Low-Energy Approach To Epinucleus Management In Phacoemulsification — Outcomes In 3,500 Eyes

The Spin-And-Flip Technique: A Standardized, Low-Energy Approach To Epinucleus Management In Phacoemulsification — Outcomes In 3,500 Eyes

Published 2026 - 44th Congress of the ESCRS

Reference: POCAT294 | Type: Free paper | DOI: 10.82333/5pc8-rt97

Authors: Dr Raashid Maqbool Wani* 1

1Phaco Refractive,Kashmir Eye Hospitals,Srinagar, Kashmir,India

Purpose

To evaluate the safety, reproducibility, and intraoperative outcomes of a standardized epinucleus management approach, termed the Spin-and-Flip Technique, during phacoemulsification across varied cataract grades. This method preserves the epinuclear bowl during nucleus removal, enabling controlled epinucleus mobilization and low-parameter aspiration while maintaining posterior capsule protection.

Setting

Retrospective analysis of 3,500 consecutive eyes undergoing phacoemulsification by a single surgeon at a tertiary eye care centre, covering a broad spectrum of cataract densities and complexity. All surgeries were performed with standardized instruments and consistent phacoemulsification platforms.

Methods

Following complete hydrodissection and hydrodelineation, the intact epinucleus was preserved during nucleus emulsification. The epinuclear bowl was gently spun using the posterior surface of the phaco chopper and flipped en masse into the central safe zone with a controlled sweeping side-tip movement. Epinucleus aspiration was completed under ultra-low parameters (longitudinal power 20%, vacuum 250 mmHg, aspiration flow rate 20 cc/min), ensuring continuous posterior capsule protection.

Results

The technique was applied successfully across all cataract densities, from soft to brunescent. Preservation of the epinuclear shell provided consistent posterior capsule shielding, facilitating controlled aspiration with minimal turbulence and ultrasound energy. Intraoperative complications were uncommon: posterior capsule rupture in 2 eyes (0.057%), zonular dialysis in 3 eyes (0.086%), and vitreous loss in 1 eye (0.029%). No case required conversion to extracapsular cataract extraction; all complications were managed intraoperatively without adverse visual outcomes.

Conclusions

The Spin-and-Flip Technique represents a structured, low-energy refinement of epinucleus management during phacoemulsification that enhances posterior capsule safety and surgical control. Its reproducibility and favorable safety profile across a large series support its integration into routine cataract surgery, offering a pragmatic approach to epinucleus removal with minimal complications.