Purpose

To present surgical results of explanting and re-implanting IOL in presence of pre-existing Iris Implant

Setting

MVZ Ostbayern

Methods

Temporal conjuntival incision followed by 5mm-scleral incision temporally. The decentrated IC-8™ IOL (Bausch&Lomb) was removed through the scleral incision and anterior vitrectomy was performed. A new 3-piece IOL (Kowa Japan) was inserted and sclerally fixed using pflanged haptic technique. All incisions were closed successfully 

Results

Post operatively IOL centration was excellent and no dislocation of the pflanged haptics were notices. Anterior chamber was deep and the pre-implanted Humanoptix Iris impant did not suffer any damage or decentration. Surgey was uneventful 

Conclusions

Operating through a scleral temporal incision could help in preserving the alreay implanted Humanoptix Iris implant without the need to explant and re implant it, making the surgery shorter and safer