Explantation Of A Dislocated Intraocular Lens With Simultaneous Reimplantation Using Flanged Loop Transscleral Monofixation In An Eye With High Hyperopia: A Case Report
Published 2026 - 44th Congress of the ESCRS
Reference: POCAT079 | Type: Case Report | DOI: 10.82333/tdht-qk87
Authors: Dr Ahmadjon Nozimov* 1 , Dr Azamat Yusupov 1 , Dr Kamila Bazarbaeva 1
1Republican Specialised Scientific and Practical Medical Centre for Eye Microsurgery ,Tashkent,Uzbekistan
Purpose
To report the clinical outcome and technical feasibility of simultaneous explantation of a dislocated intraocular lens (IOL) with immediate reimplantation utilizing flanged loop transscleral monofixation technique in a highly hyperopic eye following clear lens extraction.
Setting
We report a case of a 35-year-old patient with grade II dislocation of the IOL–capsular bag complex after clear lens extraction for high hyperopia. The dislocated hydrophilic IOL was explanted in fragments through a corneoscleral tunnel with preservation of fibrosed capsular remnants. A +40.0 D foldable posterior chamber IOL was reimplanted using flanged loop transscleral monofixation. Postoperative UBM confirmed stable IOL positioning, followed by Nd:YAG posterior capsulotomy.
Report of case
Results:
Stable centration and optimal posterior chamber positioning of the reimplanted IOL were achieved and maintained throughout the follow-up period, with no clinical or radiographic evidence of recurrent dislocation. Uncorrected distance visual acuity (UDVA) demonstrated significant improvement from 0.1 (20/200) preoperatively to 0.6 (20/30) postoperatively. Best-corrected distance visual acuity (BCDVA) improved to 0.8 (20/25). Ultrasound biomicroscopy confirmed sustained long-term biomechanical stability of the transscleral IOL fixation without evidence of suture erosion, haptic displacement, or inflammatory complications.
Conclusion/Take home message
Simultaneous explantation and reimplantation of a dislocated IOL using the flanged loop transscleral monofixation technique represents a safe, efficacious, and surgically practical approach in eyes with high hyperopia and compromised capsular support. This technique provides reliable IOL fixation with favorable refractive and anatomical outcomes in complex clinical scenarios characterized by extreme refractive error and insufficient zonular or capsular integrity. Further investigation with larger case series and extended follow-up is warranted to establish long-term safety and efficacy parameters.