Non-Diffractive Spiral Optic Iol Implantation After Refractive Lens Exchange In A Fuchs Dystrophy Patient With Angle Closure
Published 2026 - 44th Congress of the ESCRS
Reference: POCAT078 | Type: Case Report | DOI: 10.82333/vs3a-7396
Authors: Dr Ali Nowrouzi* 1
1Department of cornea and Refractive surgery,Hospital Quironsalud Marbella,Marbella ,Spain
Purpose
To evaluate visual outcomes and patient satisfaction following bilateral implantation of a non-diffractive spiral optic intraocular lens in a patient with Fuchs dystrophy and angle closure after refractive lens exchange.
Setting
Cornea and refractive surgery department of Quironsalud Hospital, Marbella, Spain.
Report of case
Methods
This is a prospective case report of a 45 years-old patient with Fuchs endothelial dystrophy and angle closure who underwent bilateral refractive lens exchange followed by implantation of a non-diffractive spiral optic intraocular lens. Intervention included standard phacoemulsification with IOL implantation. Outcome measures included uncorrected and corrected visual acuity, contrast sensitivity, patient-reported satisfaction, and quality of vision assessed at follow-up visits with VF-14 quiestionaire.
Results
Postoperatively, uncorrected distance visual acuity was 20/15 in both eyes, with uncorrected intermediate and near visual acuity of 20/20. The VF-14 questionnaire demonstrated high functional scores, with the patient reporting excellent quality of vision and no halos or night-vision disturbances. Overall satisfaction was maximal, and outcomes were statistically significant compared with the preoperative baseline.
Conclusion/Take home message
Conclusion
Bilateral implantation of a non-diffractive spiral optic IOL after refractive lens exchange provided excellent visual acuity, high functional performance, and patient satisfaction in a Fuchs dystrophy patient with angle closure, supporting its safety and effectiveness in complex cases.