Corneal Wound Dehiscence Remote From Radial Keratotomy Scars During Phacoemulsification: Evidence Of Global Biomechanical Compromise In A Bilateral Case
Published 2026 - 44th Congress of the ESCRS
Reference: POCAT046 | Type: Case Report | DOI: 10.82333/4644-en18
Authors: Dr Yaren Guven* 1 , Dr FATMA SUMER 1
1OPHTHALMOLOGY,RECEP TAYYIP ERDOGAN UNIVERSITY ,RIZE,Türkiye
Purpose
To report a case of intraoperative corneal wound dehiscence at the clear corneal incision site—remote from
radial keratotomy (RK) scars—during IOL cartridge insertion in phacoemulsification, 23 years after 8-
incision bilateral RK. Bilateral comparison with an uneventful fellow eye operated by the same surgeon
using identical technique highlights that RK globally compromises corneal biomechanical integrity beyond
the scar sites themselves, with implications for surgical planning and risk counseling.
Setting
Tertiary care university hospital, Department of Ophthalmology, Recep Tayyip Erdogan University, Rize,Turkey.
A 67-year-old male with bilateral age-related cataract presented for surgery. He had undergone bilateral 8-
incision radial keratotomy (RK) 23 years previously. Preoperative slit-lamp examination revealed well-
healed RK scars in both eyes. IOL power was calculated using the Barrett True-K formula to account for
post-RK corneal changes. Sequential bilateral phacoemulsification was planned.
Report of case
The right eye was operated first. Standard phacoemulsification with a 2.8 mm temporal clear corneal
incision, positioned away from the RK scars, was performed uneventfully. IOL was inserted via cartridge
injector system without complication and postoperative course was unremarkable.
The left eye subsequently underwent the identical surgical procedure by the same surgeon using the same
2.8 mm clear corneal incision technique, again deliberately placed away from the RK scars.
Phacoemulsification was completed without difficulty. However, during IOL cartridge insertion, the
mechanical stress of advancing the injector through the main wound caused sudden corneal wound
dehiscence at the incision site. Critically, the dehiscence originated from the clear corneal wound itself—not
from an adjacent RK scar—suggesting that the 8-incision RK had globally compromised corneal
biomechanical integrity rather than creating only focal areas of weakness. The wound gape resulted in
anterior chamber shallowing and loss of a controlled surgical environment. The IOL was successfully
implanted and three interrupted 10-0 nylon sutures were placed to restore wound integrity. The anterior
chamber was reformed and confirmed watertight.
Postoperative recovery of the left eye was prolonged compared to the right due to suture-induced
astigmatism. Selective suture removal was performed to optimize the refractive outcome, ultimately
achieving satisfactory visual acuity.
Conclusion/Take home message
Despite identical surgical technique,2.8 mm incision placed away from RK scars,and the same surgeon,only
one eye experienced wound dehiscence during IOL cartridge insertion-underscoring the unpredictable
nature of post-RK corneal vulnerability even 23 years postoperatively.Key lessons:RK weakens the
entire corneal structure;positioning incisions away from scars does not eliminate dehiscence risk;8-
incision RK creates greater biomechanical compromise than 4-incision patterns;surgeons should
consider smaller incisions,manual IOL insertion,or wound-assist devices to minimize mechanical stress;10-0 nylon sutures should be immediately available;patients must be counseled regarding
prolonged visual recovery due to potential suture-induced astigmatism.