To Assess The Impact Of Spiral And Diffractive Optical Designs On Dysphotopsia And Visual Range / Outcome
Published 2026 - 44th Congress of the ESCRS
Reference: FP32.01 | Type: Free paper | DOI: 10.82333/7vz3-x386
Authors: Dr Kieren Darcy* 1 , Nancie Edwards 1
1Vision Care Clinic,Bristol,United Kingdom
Purpose
Setting
Single surgeon, single UK clinic.
Methods
In this prospective comparative clinical study, eyes implanted with a refractive spiral IOL (RayOne Galaxy, Rayner; n=98) or a diffractive multifocal IOL (FineVision, BVI; n=22) were assessed at 3 months. Outcomes included refractive accuracy, monocular and binocular visual acuity (distance, intermediate 66 cm, near 40 cm), and defocus curves. Contrast sensitivity (SCV-1000) was measured under photopic and mesopic conditions. Dysphotopsia was evaluated using halo/glare simulation and Aston halometry.
Results
At 3 months, the spiral IOL demonstrated tighter SEQ clustering (91% within ±0.50 D vs 82%) and lower residual astigmatism ≤0.50 D (90% vs 59%). Both IOLs maintained binocular visual acuity within 0.20 logMAR supporting effective full-range functional vision. Contrast sensitivity was similar photopic ally; mesopic performance showed a trend favoring the spiral design at higher spatial frequencies.Dysphotopsia profiles differed meaningfully. Halo size and intensity were lower with Galaxy (27 vs 42; 42 vs 66), confirmed by reduced halometry area (4.66% vs 7.65%).
Conclusions
Optical design influenced the relationship between visual range performance and dysphotopsia profile. Although both IOLs provided effective functional vision, distinct photic-phenomena patterns were observed, with potential clinical relevance for patients sensitive to halos or with higher night-driving demands. Ongoing research is evaluating the impact of individual dysphotopsia tolerance, night-vision requirements, and patient-related factors on optimized lens selection.