Effect Of Capsular Tension Ring On Rotational Stability Of Loop-Haptic Intraocular Lens In Highly Myopic Patients
Published 2026 - 44th Congress of the ESCRS
Reference: FP24.14 | Type: Free paper | DOI: 10.82333/jd86-1j58
Authors: Dr Pingjun Chang* 1 , Hongzhe Li 1
1Eye Hospital of Wenzhou Medical University,Hangzhou,China
Purpose
To compare the rotational stability, tilt and decentration of loop-haptic intraocular lenses (IOLs) in highly myopic patients with and without capsular tension ring (CTR) implantation.
Setting
Eye Hospital of Wenzhou Medical University, Hangzhou, China
Methods
Consecutive highly myopic patients (axial length ≥ 26.00 mm) scheduled to undergo phacoemulsification with loop-haptic IOL implantation were randomly assigned to receive either CTR implantation or no CTR. The axial orientation of the IOL was measured at the end of surgery (EOS), and at 1 day, 1 week, 1 month, and 3 months postoperatively. Swept-source optical coherence tomography was performed at each follow-up visit to evaluate the tilt and decentration of IOL.
Results
A total of 36 eyes with CTR implantation and 36 eyes without CTR were included. Absolute IOL rotation was significantly lower in the CTR group than in the Non-CTR group from EOS to 1 day (P = 0.039) and from EOS to 3 months (P = 0.018). Subgroup analysis demonstrated that CTR implantation significantly reduced IOL rotation in eyes with thick crystalline lenses (P = 0.041). Although the CTR group consistently exhibited slightly lower values of tilt and decentration at each follow-up visit, the differences were not statistically significant (All P > 0.05).
Conclusions
CTR implantation improves the postoperative rotational stability of loop-haptic IOLs and mitigates the effect of thick crystalline lenses in highly myopic patients, while having no significant impact on IOL tilt or decentration.