ESCRS - FP06.03 - Enhancing The Diagnostic Precision Of Subclinical Keratoconus By Combining Indices From Scheimpflug Tomography, Corneal Biomechanics, And Anterior Segment Optical Coherence Tomography

Enhancing The Diagnostic Precision Of Subclinical Keratoconus By Combining Indices From Scheimpflug Tomography, Corneal Biomechanics, And Anterior Segment Optical Coherence Tomography

Published 2026 - 44th Congress of the ESCRS

Reference: FP06.03 | Type: Free paper | DOI: 10.82333/0n80-8y70

Authors: A/Prof. Wan Haslina Halim* 1 , Dr Norsyariza Razak 1 , Bariah Ali 1

1Ophthalmology,Universiti Kebangsaan Malaysia,Kuala Lumpur,Malaysia

Purpose

To determine the diagnostic precision of multi-modal corneal imaging for detection of subclinical keratoconus (SKC).

Setting

Ophthalmology Clinic, Hospital Canselor Tunku Mukhriz, Kuala Lumpur, Malaysia.

Methods

All subjects in this prospective, cross-sectional study underwent Scheimpflug tomography (Pentacam HR), air-puff tonometry (Corvis ST), and spectral-domain optical coherence tomography (Cirrus HD SD-OCT). Combined diagnostic models were developed using stepwise logistic regression (SLR). The Kruskal–Walli’s test evaluated group differences. Diagnostic accuracy was assessed by calculating the area under the curve (AUC).

Results

A total of 137 participants were assessed ( 48 KCN , 36 SKC, and 53 normal). Most examined tomography, biomechanical, and pachymetry indices showed significant differences between KCN, SKC, and normal eyes (p<0.05). Single Tomographic Biomechanical Index, (TBI) data was most effective in identifying SCKC, achieving an AUC of 0.978 (p<0.001) with 100% sensitivity and 84.91% specificity. Combining SD-OCT and Pentacam HR data, the SLR model yielded superior accuracy for SKC detection, with an AUC of 0.966 (91.67% sensitivity and 100% specificity). The highest accuracy for SCKC identification was attained by integrating data from all three devices, resulting in 0.990 accuracy (86.91% sensitivity; 96.13% specificity).

Conclusions

Integrating a Scheimpflug-based biomechanical and tomography analyser with SD-OCT improves the precision of SCKC detection. This combined approach supports more accurate SKC screening and assists clinicians in identifying early disease in patients with otherwise normal findings.