ESCRS - PP22.04 - Higher Order Aberrations And Modulation Transfer Function In Eyes With Asymmetric Refractive Edof And Trifocal Iol

Higher Order Aberrations And Modulation Transfer Function In Eyes With Asymmetric Refractive Edof And Trifocal Iol

Published 2025 - 43rd Congress of the ESCRS

Reference: PP22.04 | Type: Free paper | DOI: 10.82333/d3pb-8p52

Authors: Jifan Wang* 1 , Xuejun Fang 2

1Department of Refractive Surgery,Liaoning Aier Eye Hospital,Shenyang,China, 2Liaoning Aier Eye Hospital,Shenyang,China

Purpose

To compare higher order aberrations (HOA) and modulation transfer function (MTF) in eyes implanted with asymmetric refractive EDOF and trifocal IOLs.

Setting

Tertiary private eye hospital, India

Methods

A retrospective study where subjects implanted with asymmetric refractive EDOF (Lentis Comfort, Teleon Surgical BV) and Trifocal IOL (PanOptix, Alcon),  aged between 40 -75 years, post-operative best corrected visual acuity 0.2logMAR or better, pre operative corneal astigmatism <1.50D and cataract grade NS I-III were included in the study. Subjects with any ocular pathologies, irregular astigmatism, previous refractive surgery, and intra-operative complications were excluded. At 1 month follow up, internal HOA (3rd, 4th and 5th order) and MTF at 5,10,15,20,25, 30 cycle per degrees were obtained using i-Trace aberrometer for 4mm fixed pupil and compared among different groups.

Results

44 and 34 eyes were implanted with asymmetric refractive EDOF and trifocal IOL respectively. The Mean±SD age of the subjects implanted with asymmetric refractive EDOF and trifocal IOL were 58.80±10.1 and 57.88±8.55 year respectively (Two sample, p=0.66). Higher order aberrations were found to be similar in both the IOLs (two sample t test, p>0.05). MTF at all spatial frequencies were also similar in both the IOLs (Two sample t test, p>0.05).

Conclusions

We noted similar internal HOA and MTF in eyes implanted with asymmetric refractive EDOF and trifocal IOL.