Nick, Loop And Pull Technique Of Corneal Suture Removal.
Published 2025 - 43rd Congress of the ESCRS
Reference: PO905 | Type: Poster | DOI: 10.82333/1z5b-dr12
Authors: Vinit Tanwar* 1
1ophthalmology ,Iclinix Advanced eye and retina care,New delhi ,India
Purpose
To devise and report a standardized step-wise approach of corneal suture removal.
Setting
Iclinix advanced eye and retina care, new delhi , india
Methods
A review of the literature and observed practiced suture removal techniques by ophthalmologists and corneal surgeons
was performed. Associated problems were noted, such as epithelial defects, wound dehiscence, and bleeding from the vascularized
cornea in deeply buried sutures. A step-wise approach was devised hitherto described as the Nick, Loop, and Pull technique,
providing a systematic step-wise method of corneal suture removal,which was tested clinically for complications.
Results
This technique was performed successfully in 20 eyes with comparatively fewer complications after corneal suture removal
compared to routine methods.
Conclusions
This standardized step-wise approach of corneal suture removal is feasible, reproducible, and easy to learn, and causes
less deleterious effects on the cornea and its wound integrity.