ESCRS - PO589 - Use Of X-Wave Technology -Based Edof Iol In A Post-Lasik Patient.

Use Of X-Wave Technology -Based Edof Iol In A Post-Lasik Patient.

Published 2024 - 42nd Congress of the ESCRS

Reference: PO589 | Type: Poster | DOI: 10.82333/zte5-vq11

Authors: Lusine Vogormian* 1 , Lizaveta Chychko 1 , Ramin Khoramnia 1 , Gerd Auffarth 1

1Ophthalmology,University Eye Clinic Heidelberg,Heidelberg,Germany

Purpose

Presbyopia correction with Extendet Depth of Focus lenses in a patient post Lasik. 

Setting

Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany.

Methods

A 64-year-old patient with bilateral condition after Lasik underwent cataract surgery with the assistance of Lensar femtosecond laser. Per the patient’s request to correct presbyopia and considering biometrical errors by condition post Lasik, the patient had implantation of wavefront-shaping AcrySof IQ Vivity intraocular lenses (from Alcon, Texas, US) with bilateral emmetropic target. 

Results

The mean binocular visual acuty presented one week post operation was [logMar] UDVA/CDVA 0,14/0,04 (0,8p/1,0p Decimal), UIVA EDTRS 40 cm – 0,8, UNVA EDTRS 80cm – 1,0). Subjective refraction, uncorrected and corrected visual acuity (VA), binocular [logMar] for distance, binocular for intermediate, as well as positive dysphotopsia and the best corrected defocus curve 1, 3 and 6 months after surgery are still under evaluation.

Conclusions

AcrySof IQ Vivity IOL considered to be a good choice, able to provide presbyopic patients with condition post-Lasik a broad range of vision, both at distance and intermediate, while minimising positive dysphotopic phenomena such as glare, halos and starbursts.