ESCRS - PO517 - New Nucleus Management Technique

New Nucleus Management Technique

Published 2024 - 42nd Congress of the ESCRS

Reference: PO517 | Type: Free paper | DOI: 10.82333/dkgn-3j58

Authors: Gaurav Mishra* 1 , Manoj Saxena 2

1Ophthalmology,Drishti Eye Doundation,Meerut,India, 2Ophthalmology,Prakash Netralaya and Retina Foundation,Aligarh,India

Purpose

To observe efficiency, safety and learning curve in all grades and types of cataract as compared to stop and chop.

Setting

Drishti Eye Foundation, Meerut, Uttar Pradesh, India

Methods

Done in 500 cases. Patients divided into two groups (250 with stop and chop and 250 torsional C Chop). Follow up was done for 1st POD, 1st
Week and 4th week. Compared complication rate, overall CDE and learning curve.

Results

Age group 50-70 years. 60% male and 40% female population. As compared to SNC (stop and chop) complication rate was reduced (1.2% Vs 4%).
Over all CDE was reduced from 10 to 7. Reduction in learning curve was also reduced.

Conclusions

The new torsional C Chop technique is more effective and safer as compared to SNC. Less learning curve was also observed.