ESCRS - PO0417 - The Accuracy Of Barrett Universal Ii Formula For Multifocal Intraocular Lens Power Calculation In Eyes With High Axial Length

The Accuracy Of Barrett Universal Ii Formula For Multifocal Intraocular Lens Power Calculation In Eyes With High Axial Length

Published 2023 - 41st Congress of the ESCRS

Reference: PO0417 | Type: Free paper | DOI: 10.82333/stqd-1469

Authors: Trang Doan Minh Dinh 1 , Huong Bui Cam* 2

1THE EYE DEPARTMENT,LONG KHANH GENERAL HOSPITAL,DONG NAI,Viet Nam, 2Viet Nga International Eye Hospital ,Ho Chi Minh city,Viet Nam

Purpose

Purpose: To assess the accuracy of Barrett Universal II (BU II) formula for multifocal intraocular lens power calculation (IOL) in eyes with high axial length.

 

Setting

MAE: Mean absolute error . MNE: Mean numerical error 

Methods

Methods: The study was done on 39 eyes that underwent phaco surgery and IOL implantation at Viet Nga hospital from 4/2022 to 8/2022. IOL power calculation was measured by four formulas: SRK/T, Haigis, Holladay 2, and BU II. Mean absolute error (MAE) and mean numerical error (MNE) were recorded at four weeks postoperatively.

Results

Results: The study included 39 eyes. 8 eyes had IOL power below -6D, and 31 eyes had IOL power greater than -6D. The BU II had the lowest MAE and MNE, which were 0,29±0,04, -0,02±0,07, respectively, among the four formulas. Statistically, a significant difference was seen between MAE of BU II with SRK/T, Haigis, Holladay 2.

Conclusions

Conclusions: The study shows that the BU II formula has the lowest spherical error in eyes with an axial length greater than 25 mm.