ESCRS - PO0404 - Iol Exchange After Wrong Dioptric Power Iol Implantation During The Primay Cataract Operation.

Iol Exchange After Wrong Dioptric Power Iol Implantation During The Primay Cataract Operation.

Published 2023 - 41st Congress of the ESCRS

Reference: PO0404 | Type: Free paper | DOI: 10.82333/wpba-cq48

Authors: John Mallias* 1

1LASER PLUS EYE INSTITUTE,Nea Smyrni, Athens,Greece

Purpose

 To report a case series of 10 patients with implantation of IOL of wrong dioptric power who underwent a second operation with IOL exchange.

Setting

LaserPlusEye Institute

Methods

The patients were operated with intravenous  sedation and Para bulbar  anesthesia. At the beginning of the procedure the main incision was reopened and viscoelastic was injected in the anterior chamber, mobilizing the pre-existing lens and releasing it from the capsular bag and relocate it to the anterior chamber. Subsequently, the new IOL was injected in the capsular bag and then the older intraocular lens was cut with special intraocular cutting scissors and the pieces were removed from the main incision.

Results

The patients had excellent results despite the fact that in some intraoperative cases a small bleeding occurred. All patients regained full vision and had no postoperative complications.

Conclusions

The replacement of intraocular lens in cases of patients in which an incorrect intraocular lens was placed  is a safe procedure with good visual results.