VISUAL AND TOMOGRAPHIC OUTCOMES OF LONG ARC-LENGTH ICRS IMPLANTATION IN MODERATE TO ADVANCED KERATOCONUS
Published 2023
- 27th ESCRS Winter Meeting
Reference: P124
| Type: Free Paper Submission
| DOI:
10.82333/wd86-7178
Authors:
André Ferreira* 1
, João Ramalhão 2
, Miguel Mesquita Neves 2
, Miguel Gomes 2
, Luís Oliveira 2
1Department of Ophthalmology,Centro Hospitalar Universitário do Porto,Porto,Portugal;Department of Biomedicine,Faculty of Medicine, University of Porto,Porto,Portugal, 2Department of Ophthalmology,Centro Hospitalar Universitário do Porto,Porto,Portugal
Purpose
To assess the outcomes of implanting an intrastromal corneal ring segment (ICRS) of 300º or above arc-length in moderate to advanced hyperprolate keratoconus (KC).
Setting
Cornea Unit, Department of Ophthalmology, Centro Hospitalar Universitário do Porto
Methods
Retrospective study enrolling patients with moderate to advanced hyperprolate KC that were submitted to femtosecond laser-assisted implantation of a long arc-length ICRS (Ferrara or Kearing). The clinical measurements taken included manifest refraction, best-corrected distance visual acuity (BCDVA, logMAR scale), and corneal tomographic analysis (Oculus Pentacam HR (OCULUS Optikgerate GmbH, Wetzlar, Germany)). Changes in keratometry, asphericity, and the root mean square (RMS) for total higher-order and coma-like aberrations for a pupil size of 4.5 mm were evaluated. All examinations were performed before surgery and at least 3 months after surgery.
Results
Sixteen eyes of 15 patients (60% men) with a mean±SD age of 25.36±8.76 years were enrolled. Mean±SD BCDVA improved from 0.68±0.12 to 0.43±0.05 LogMAR (P = 0.014) and the spherical equivalent reduced from -2.19±0.58 to -0.69±0.33D (P = 0.025). All keratometric parameters reduced significantly (all P < 0.001; mean±SD 54.17±42 vs 48.02±2.65 for K1, 58.87±4.89 vs 51.19±2.59 for K2 and 69.90±7.90 vs 61.58±4.60 for Kmax). The asphericity reduced significantly (+0.96±0.44; P < 0.001). The absolute values of horizontal and vertical Coma-like aberrations reduced -0.32±0.17 (P = 0.034) and -0.38±0.22 (P = 0.055), respectively, and the total higher-order aberrations were also lower after ICRS implantation (-1.21±0.19, P < 0.001). No complications occured during or after the procedure.
Conclusion
These results suggest that implanting a long arc-length ICRS is a safe and effective procedure for treating patients with moderate to advanced hyperprolate keratoconus and clear cornea, leading to improvement of visual and tomographic outcomes.