ESCRS - P121 - SCLERAL SHAPE AND ITS CORRELATIONS WITH CORNEAL PARAMETERS IN KERATOCONUS

SCLERAL SHAPE AND ITS CORRELATIONS WITH CORNEAL PARAMETERS IN KERATOCONUS

Published 2023 - 27th ESCRS Winter Meeting

Reference: P121 | Type: Presented Poster & Poster Submission | DOI: 10.82333/et6m-2486

Authors: Alejandra Consejo* 1 , Siska Dhaese 2 , Elke O. Kreps 2

1Applied Physics,University of Zaragoza,Zaragoza,Spain, 2Ophthalmology,Ghent University Hospital,Ghent,Belgium

Purpose

Information on the scleral shape is fundamental for an optimal scleral lens fit, a key vision correcting device in keratoconus patients. The aim of the current work is to assess the correlation of the scleral shape and corneal tomographic parameters in keratoconus.

Setting

Department of Ophthalmology, Ghent University Hospital

Methods

Twenty eyes of 15 keratoconus patients with no previous specialty lens wear or ocular surgery were included in this study. Corneal imaging was obtained with the Pentacam HR and three-dimensional (3D) corneoscleral maps were acquired using the Eye Surface Profiler, ESP. Sagittal height was calculated at the central corneal level (annulus of 0–4 mm radius), peripheral cornea (annulus 4–6 mm radius) and sclera (annulus 6–8 mm radius) using ESP maps and Pentacam HR (exclusively for the central cornea). The flattest and steepest regions of each annulus and the circumferential scleral asymmetry were calculated based on custom-made software. The Pearson correlation coefficient (r) was used to evaluate the correlation between corneal parameters as measured by Pentacam HR and scleral asymmetry.

Results

Anterior corneal parameters, such as flattest and steepest keratometry, were found to be correlated with scleral asymmetry in keratoconus (all r>0.5, p < 0.05). In contrast, anterior astigmatism showed poor correlation with the level of scleral irregularity (r=-0.11; p = 0.32). Other disease-specific parameters pertaining to the posterior corneal curvature and corneal thickness were not correlated with scleral asymmetry. The steepest regions of the central cornea, peripheral cornea, and sclera tended to share a common angle (r = 0.92; p < 0.001 for central cornea compared to sclera).

Conclusion

Anterior corneal parameters measured by corneal imaging are associated with the level of scleral asymmetry and the orientation of the steepest area of the sclera in eyes with keratoconus. It is not possible to accurately describe scleral shape from corneal topography but it is possible to infer certain parameters, such as steepest scleral meridian which are of use in scleral lens fit.