PSEUDOMONAS DETECTION WITH OCT IN KERATITS
Published 2023 - 27th ESCRS Winter Meeting
Reference: P110 | Type: Free Paper Submission | DOI: 10.82333/ex51-g075
Authors: Haidar Khalil* 1 , Klemens Waser 1 , Peter Laubichler 1 , Leon Pomberger 1 , Bolz Matthias 1 , Nino Hirnschall 1
1Department of Ophthalmology and Optometry,Johannes Kepler University,Linz,Austria
Purpose
Pseudomonas is one of the leading causes for bacterial keratitis, predominatly in contact lens users. Conventional corneal scraping with bacterial culturing has several disadvantages such as long duration until diagnosis, invasiveness and low sensitivity. There is demand for a novel non-invasive, rapid test in Pseduomonas keratitis management. Purpose of this study is to investigate certain OCT patterns pathognomonic for pseudomonas.
Setting
Prospective clinical trial. Patients will be recruited from the outpatient clinic of the Department of Ophthalmology, Kepler University Clinic, Linz, Austria.
Methods
Measurement of the Cornea in patients with keratitis are performed using CASIA 2 (Tomey, Japan), which is a SS-OCT that allows high resolution imaging of the anterior segment of the eye. Following morphological findings in optical coherence tomography were analysed: corneal thickness (μm), infiltrate thickness (μm), entropy of the infiltrate area (measured using ImageJ). Corneal scraping was performed to determine the underlying pathogen.
Results
From our cohort of 25 eyes, 7 eyes had a keratitis due to pseudomonas. Mean age in the keratitis group was 26 years. In 6 of those eyes, keratitis was associated to contact lens wear and one was due to a trauma. Mean corneal thickness was 820µm (SD +/- 193µm), mean infiltrate thickness 347µm (SD +/- 125µm). Mean tissue gain ratio of 1.3 was measured in the area of the infiltrate, compared to the not affected side of the cornea in the same eye. Partial least squares regression model was used to determine parameters that have influence on the detection of pseudomonas.
Conclusion
Tissue gain in the area of infiltrate, history of contact lens use and a large infiltrate thickness. Boot strapping was used to evaluate the regression model, showing high confidence interval.