ESCRS - P067 - EVALUATION OF PATIENT’S VISUAL PERFORMANCE AFTER IMPLANTATION OF EXTENDED DEPTH-OF-FOCUS ACRYSOF® VIVITY® INTRAOCULAR LENS.

EVALUATION OF PATIENT’S VISUAL PERFORMANCE AFTER IMPLANTATION OF EXTENDED DEPTH-OF-FOCUS ACRYSOF® VIVITY® INTRAOCULAR LENS.

Published 2023 - 27th ESCRS Winter Meeting

Reference: P067 | Type: Presented Poster & Poster Submission | DOI: 10.82333/c0qn-nm08

Authors: Wojciech Luboń* 1 , Małgorzata Luboń 1 , Ewa Mrukwa-Kominek 1

1Department of Ophthalmology, University Clinical Center, Katowice, Poland,University Clinical Center, Katowice, Poland,Katowice,Poland

Purpose

Aim of the work.
The aim of the study is to evaluate the patient’s performance and quality of life related to vision after implantation of extended depth-of-focus AcrySof® Vivity® intraocular lens.

Setting

Setting: Qualification of patients, surgery and all follow-ups were carried out in the Department of Ophthalmology of University Clinical Centre in Katowice.

Methods

15 patients (30 eyes) with cataract were qualified for implantation of AcrySof® Vivity® intraocular lens. The power of implanted lenses was calculated for emmetrophy. After surgery follow-up visits were planed 14 days, 1,3 and 6 months after surgery. Detailed ophthalmic evaluation was done including uncorrected visual acuity for far, intermediate and near distances, residual refraction using maximum plus technique, defocus curve, contrast sensitivity, life quality related to vision using VF-14 questionnaire and assessment of halo and glare. 

Results

UCDVA was 0.01 logMAR (-0.18-0.2), mean UCIVA at 70 cm was 0.14 logMAR 

 (0.1-0.3), mean UCNVA for 40cm was 0.38 logMAR (0.2-0.5). Mean residual refractive error was less than -0,25D. Mean result of VF-14 questionnaire was 88/100 points. Occurrence of halo and glare was very low and none of the patient reported  halos or glare disturbing driving at night.

Defocus curve showed visual acuity within 0.2 logMAR up to distance of 45-50 cm.

Conclusion

AcrySof® Vivity® intraocular lens provides good visual acuity for distant and intermediate distances. Rate of adverse visual effects is very low. This intraocular lens provide high patients satisfaction.