RADIATION-INDUCED CATARACT IN A RADIOLOGY HEALTH PROFESSIONAL.
Published 2023 - 27th ESCRS Winter Meeting
Reference: P027 | Type: Presented Poster & Poster Submission | DOI: 10.82333/nmy8-xy30
Authors: Mohcine El Mhadi* 1 , Aziz El ouafi 1 , Adil Bouzidi 1 , Ahmed Alami 1 , Said Iferkhass 1
1Ophthalmology department,Military hospital Moulay Ismail of Meknes,Meknes,Morocco
Purpose
We report a case of radiation-induced cataract in a radiology health professional to describe its pathogenesis, its clinical aspect in order to prevent it.
Setting
Methods
The slit lamp examination shows in the right eye: A clear cornea, a normal anterior chamber and a posterior subcapsular cataract.The rest of the exam is unremarkable.
Given his good corrected visual acuity, the patient is fitted with corrective lenses. Phacoemulsification surgery with placement of an intraocular implant will be considered depending on the evolution.
Results
Regarding the minimum dose likely to cause a radiation-induced cataract In 1950, Merriam proposed a range between 5 and 15 Grays (Merriam and Worgul, 1983)
In 1957, they proposed a threshold of 2 Gy for a single dose and 4 Gy for a dose divided and/or spread over time (Merriam and Focht, 1957).
For the Time to onset, it can vary between 6 months and 35 years; the average would be around 2 to 3 years (Merriam and Worgul, 1983).
From the point of view of radiation protection regulations, the Labor Code stipulates that: “for the lens, the exposure received during twelve consecutive months cannot exceed 150 mSv” (Labour Code, 2008).
A worker is considered to be at risk insofar as he is likely to receive an equivalent dose to the lens of more than 15 mSv per year (“public” dose). This is particularly the case for certain hospital staff, particularly in interventional radiology.
In addition to implementing conventional protection measures against ionizing radiation, interventional radiologists and other professionals assisting them are strongly recommended to systematically wear lead-glass glasses, since they reduce the dose received by 80%. These lead glasses can be adapted to the view
Conclusion