ESCRS - O38 - SUBJECTIVE AND OBJECTIVE COMPARISON OF TWO ADVANCED MONOFOCAL INTRAOCULAR LENSES

SUBJECTIVE AND OBJECTIVE COMPARISON OF TWO ADVANCED MONOFOCAL INTRAOCULAR LENSES

Published 2023 - 27th ESCRS Winter Meeting

Reference: O38 | Type: Free Paper Submission | DOI: 10.82333/8qnd-mh87

Authors: José Manuel Salgado-Borges* 1 , Anabela Borges 1 , Isabel Ferreira 1 , José González-Méijome 2 , Miguel Faria-Ribeiro 2

1Ophthalmology,Clinica Oftalmológica Salgado Borges,Porto,Portugal, 2Physics,University of Minho,Braga,Portugal

Purpose

To compare the subjective depth-of-field, objective optical quality, and refractive power profile of two advanced monofocal intraocular lenses (IOLs) designed to improve the intermediate vision of pseudophakic patients.

Setting

Clinsborges. Porto, Portugal and Physics Center of Minho and Porto Universities (CF-UM-UP) - University of Minho, Braga, Portugal

Methods

This prospective study evaluated forty-six eyes of twenty-three patients, aged 54-86 years, of whom 12 were implanted binocularly with IOL IsoPure 123 (PhysioI, Belgium) and 11 with IOL Tecnis Eyhance (Johnson&Johnson, NL). All patients presented a monocular uncorrected visual acuity at distance of at least 0.1 logMAR, posterior capsule transparency and an average pupillary diameter of 3.60±0.60mm (mean±sd). Subjective through-focus visual acuity curves were obtained by overlapping trial lenses to the best spherical-cylindrical correction for distance, in steps of -0.50D, between +0.50D and - 2.00D. The objective optical quality was defined as the area under the modulation transfer function (MTFa), integrated between 0 and 50 cycles/mm, calculated using Fourier optics methods directly from the wavefront values obtained with the Osiris-T high resolution aberrometer (CSO, Italy). The optical characterization of both lenses was made based on their refractive power profile measured with the NIMO TR1504 Interferometer (Lambda-X, Belgium), with the lenses immersed in saline solution.

Results

The power profiles of both lenses show an IOL design with a progressive center-near aspherical geometry, in which the sagittal power decreases rapidly from the center of the optical zone to reach the nominal power at about 0.87 mm from the center (IsoPure +23.14D to +20.00D; Eyhance from +22.50D to +20.00D, from 0 to 0.87 mm). Comparison between mean monocular through-focus curves show a best corrected distance visual acuity of 0.0 logMAR (+1 letter) with both lenses. Through-focus visual acuity was marginally higher for the Eyhance, with a difference of only 1 letter at the defocus position of -0.50D (2m) and of about 3 letters at the defocus positions between -1.00D and -2.00D (1m to 0.5m). These differences were not statistically significant for a 95% confidence level. Objective assessment of optical quality based on wavefront measurements revealed only a clinically and statistically insignificant marginal difference in best corrected distance optical quality, with a higher value in MTFa obtained with the IsoPure (36.28±1.62 vs.35.01±1.97, mean±IC95%) and almost undifferentiated through-focus image quality from -0.50D to -2.00D defocus positions.

Conclusion

Both IOLs use a similar approach to enhance the depth-of-focus and improve intermediate vision. The small differences observed in the optical design of these special IOLs do not produce a functional difference, since both lenses present similar subjective and objective through-focus curves.