1Breyer-Kaymak-Klabe Eye Surgery & premium Eyes, Düsseldorf,Breyer-Kaymak-Klabe Eye Surgery & premium Eyes, Düsseldorf,Düsseldorf,Germany, 2Makula-Netzhaut-Zentrum – MVZ Breyer Kaymak Klabe Oberkassel,Makula-Netzhaut-Zentrum – MVZ Breyer Kaymak Klabe Oberkassel,Düsseldorf,Germany, 3Internationale Innovative Ophthalmochirurgie ,Breyer-Kaymak-Klabe Eye Surgery & premium Eyes, Düsseldorf,Düsseldorf,Germany, 4Augentagesklinik Rheine, Rheine,International Vision Correction Research Centre (IVCRC), University of Heidelberg,Rheine,Germany, 5University-Eye-Clinic, Heidelberg,International Vision Correction Research Centre (IVCRC), University of Heidelberg,Heidelberg,Germany

Purpose

The purpose of this investigation is to evaluate a possible increase of the quality of vision in distances between far and intermediate range by using a new enhanced monofocal “EDoF” IOL.

Setting

All surgeries were / will be performed at the Breyer-Kaymak-Klabe Eye Surgery and Premium Eyes in Duesseldorf, Germany, member of the International Vision Correction Research Center (IVCRC.net) by one single surgeon (Breyer).

 

Methods

In all eyes (n=18), a hydrophilic enhanced monofocal IOL (LENTIS® L-333, Teleon Surgical GmbH) was implanted. We retrospectively as part of a quality management of lenses assessed subjective refraction, monocular and binocular uncorrected and best distance corrected visual acuity for far and intermediate distances, and binocular defocus capacity after 3 months postoperatively. Halo and Glare phenomena are evaluated. 

Results

The new enhanced monofocal EDoF IOL allows unimpaired seeing at distance. LENTIS L-333 shows clinically significant enhanced EDoF effect in intermediate VA. Therefore, this IOL is an “inbetween” solution of a monofocal and an EDoF IOL.  No Halo and Glare were detected.    

Conclusion

LENITS L-333 IOL is a very interesting alternative to classical monofocal IOL. This IOL enables a higher degree of independence from glasses than monofocal IOL (high safety and comfort level) without more photopic phenomena as in classical aspheric monofocal IOL. It is also possible to apply micro monovision and monovision blended vision (Düsseldorf formula) with these IOLs even achieve a higher independence from glasses.