PREDICTION OF RESIDUAL ASTIGMATISM USING INTRAOPERATIVE WAVEFRONT ABERROMETRY VERSUS MULTIPLE TORIC IOL CALCULATORS
Published 2022 - 26th ESCRS Winter Meeting
Reference: FP37 | Type: Abstracts | DOI: 10.82333/c30q-2s03
Authors: Telmo Cortinhal* 1 , Jorge Simão 2 , Miguel Raimundo 3 , Joaquim Murta 4
1Ophthalmology Department,Centro Hospitalar e Universitário de Coimbra,Coimbra,Portugal, 2Ophthalmology Department,Centro Hospitalar e Universitário de Coimbra,Coimbra,Portugal;Faculty of Medicine,University of Coimbra (FMUC),Coimbra,Portugal;Clinical Academic Center of Coimbra,(CACC),Coimbra,Portugal, 3Ophthalmology Department,Centro Hospitalar e Universitário de Coimbra ,Coimbra,Portugal;Unidade de Oftalmologia de Coimbra ,(UOC),Coimbra,Portugal;Faculty of Medicine,University of Coimbra (FMUC),Coimbra,Portugal;Clinical Academic Center of Coimbra,(CACC),Coimbra,Portugal, 4Ophthalmology Department,Centro Hospitalar e Universitário de Coimbra,Coimbra,Portugal;Faculty of Medicine,University of Coimbra (FMUC),Coimbra,Portugal;Unidade de Oftalmologia de Coimbra,(UOC),Coimbra,Portugal;Clinical Academic Center of Coimbra,(CACC),Coimbra,Portugal
Purpose
The Barrett Toric IOL calculator offers excellent performance by including estimation of posterior corneal astigmatism and effective lens position. The option of including measured posterior corneal astigmatism is also available. Recently, the Kane Toric formula was introduced. Intraoperative Wavefront Aberrometry (IWA) is an alternative method for intraoperative IOL cylindrical power selection and axis refinement. In this study we compared the prediction of residual astigmatism by each of these methods.
Setting
Ophthalmology Department, Centro Hospitalar e Universitário de Coimbra - CHUC, Coimbra, Portugal. Unidade de Oftalmologia de Coimbra (UOC), Coimbra, Portugal.
Methods
Results
The centroid prediction error was 0.15D@175±0.52 for Barrett ePCA, 0.15D@174±0.54 for Barret mPCA, 0.22D@164±0.62 for IWA and 0.24D@179±0.54 for Kane. The Barrett ePCA showed the highest proportion of eyes with a prediction error within 0.50D, 0.75D and 1D with 62%, 90% and 93% (no improvement with mPCA), followed by IWA (50%, 75%, 92%) and Kane (50%, 80%, 92%). The chosen IOL cylindrical power (T) using IWA differed from the suggested IOL cylindrical power using the Barrett ePCA in 35/60 eyes (58%) and from the Kane in 44/60 eyes (57%), with tendency lower T values using IWA compared to the Barrett.
Conclusion