Paediatric high myopia

Outcomes show favourable profile for phakic posterior chamber lens

Paediatric high myopia
Cheryl Guttman Krader
Cheryl Guttman Krader
Published: Thursday, March 1, 2018
Phakic posterior chamber lens implantation (Visian ICL, STAAR Surgical) is a good option for treating children with unilateral high myopia and moderate amblyopia who failed conventional therapy with glasses or contact lenses. This is according to data from 20 years of follow-up study presented at the 2017 WSPOS Paediatric Subspecialty Day meeting in Lisbon, Portugal. In addition to having good safety, refractive, and functional outcomes that lead to quality-of-life improvement, the Visian ICL has advantages compared with the alternatives of laser vision correction and implantation of an anterior chamber phakic IOL. “PRK and LASIK can provide good refractive results, but these require patient cooperation, modify the cornea and can lead to haze. The anterior chamber phakic IOL has not been associated with significant complications during 36 months of follow-up, but it can cause endothelial cell loss and the long-term safety is unknown,” said Laurence C Lesueur MD, Centre d’Ophtalmologie, Toulouse, France. Implantation of the posterior chamber Visian ICL is performed through a small incision and maintains integrity of the cornea. It is a reversible technique that has shown good refractive predictability and stability, and it has not been associated with significant endothelial cell loss, lens opacification, or increased IOP, she noted. Dr Lesueur and Jean L Arne MD first implanted a Visian ICL in a child in 1997. An updated review of their experience analysed data from 20 eyes of patients (mean age 8.8 years) implanted with versions V2, V3, V4b, and V4c of the lens. Mean refraction was -12.3D preoperatively and -0.4D at last follow-up (mean 9.4 years). Mean BCVA improved from 0.12 to 0.35. No eyes lost more than one line of BCVA, 66% had a BCVA gain of at least one line, and a single eye lost one line of BCVA after a traumatic retinal detachment. Presence of strabismus was reduced from 53% to 30%, as four children underwent surgery for strabismus with high angle deviation (>40D) after ICL surgery. The percentage of children with binocular vision improved from 12% to 43%. There were no late significant inflammatory reactions. One eye implanted with the V2 ICL developed moderate anterior capsule opacification. “Secondary opacification of the crystalline lens is the main risk with this phakic IOL, but cataract surgery with capsular bag implantation of a pseudophakic IOL could restore good functional vision,” Dr Lesueur said. Laurence C. Lesueur: lesueur.lc@gmail.com
Tags: lens implantation, wspos
Latest Articles
Organising for Success

Professional and personal goals drive practice ownership and operational choices.

Read more...

Update on Astigmatism Analysis

Read more...

Is Frugal Innovation Possible in Ophthalmology?

Improving access through financially and environmentally sustainable innovation.

Read more...

iNovation Innovators Den Boosts Eye Care Pioneers

New ideas and industry, colleague, and funding contacts among the benefits.

Read more...

From Concept to Clinic

Partnerships with academia and industry promote innovation.

Read more...

José Güell: Trends in Cornea Treatment

Endothelial damage, cellular treatments, human tissue, and infections are key concerns on the horizon.

Read more...

Making IOLs a More Personal Choice

Surgeons may prefer some IOLs for their patients, but what about for themselves?

Read more...

Need to Know: Higher-Order Aberrations and Polynomials

This first instalment in a tutorial series will discuss more on the measurement and clinical implications of HOAs.

Read more...

Never Go In Blind

Novel ophthalmic block simulator promises higher rates of confidence and competence in trainees.

Read more...

Simulators Benefit Surgeons and Patients

Helping young surgeons build confidence and expertise.

Read more...