A customised broad spectrum OCT device can reliably measure tear film thickness without touching the ocular surface, according to Gerhard Garhöfer MD, of the Medical University of Vienna, Austria. He expects commercial versions will be available soon that will give clinicians a user-independent measure of tear film break up time that will be helpful for diagnosing and monitoring dry eye disease.
Dr Garhöfer conducted a study using ultra-high resolution OCT for assessing tear film thickness in 60 dry eye patients before and after administration of three commercial gel lubricants: hyaluronic acid 0.15% plus 3.0% trehalose (Thealoz Duo Gel); hyaluronic acid 0.2% (Hylo Gel); polyethylene glycol 0.4% plus propylene glycol 0.3% (Systane Gel).
While 10 minutes after administration a pronounced increase in tear film thickness was observed in all three groups, hyaluronic acid with trehalose significantly maintained the increase in tear film for up to two hours, Dr Garhöfer reported.
Beyond these immediate findings on dry eye gels, the study demonstrates that high resolution OCT can measure tear film without contacting the ocular surface, and provides operator-independent results. Drawbacks of the custom device include limitation to a 3.0mm segment of the ocular surface, and the high cost of light sources that can deliver approximately 1.0 micron resolution required for tear surface evaluation, Dr Garhöfer said.
“We are working to make it larger so we can cover the whole surface so we can see exactly where the break up happens,” Dr Garhöfer said. He expects OCT machines with this capability will be commercially available soon.
Gerhard Garhöfer: gerhard.garhoefer@meduniwien.ac.at
Latest Articles
Towards a Unified IOL Classification
The new IOL functional classification needs a strong and unified effort from surgeons, societies, and industry.
Read more...
The 5 Ws of Post-Presbyopic IOL Enhancement
Fine-tuning refractive outcomes to meet patient expectations.
Read more...
AI Shows Promise for Meibography Grading
Study demonstrates accuracy in detecting abnormalities and subtle changes in meibomian glands.
Read more...
Are There Differences Between Male and Female Eyes?
TOGA Session panel underlined the need for more studies on gender differences.
Read more...
Simulating Laser Vision Correction Outcomes
Individualised planning models could reduce ectasia risk and improve outcomes.
Read more...
Mastering IOL Exchange
Tips and tricks for an uncomplicated replacement procedure.
Read more...
Need to Know: Aberrations, Aberrometry, and Aberropia
Understanding the nomenclature and techniques.
Read more...
When Is It Time to Remove a Phakic IOL?
Close monitoring of endothelial cell loss in phakic IOL patients and timely explantation may avoid surgical complications.
Read more...
Delivering Uncompromising Cataract Care
Expert panel considers tips and tricks for cataracts and compromised corneas.
Read more...
Organising for Success
Professional and personal goals drive practice ownership and operational choices.
Read more...