IOL power calculation

Ray tracing method offers several potential advantages

IOL power calculation
Leigh Spielberg
Leigh Spielberg
Published: Friday, December 1, 2017
Nino Hirnschall MD, PhD
Using a ray tracing approach for IOL power calculation offers several important potential advantages over conventional approaches, reported Nino Hirnschall MD, PhD, Vienna Institute for Research in Ocular Surgery, Austria, at the XXXV Congress of the ESCRS in Lisbon, Portugal. “There are two potential advantages of a ray tracing-based IOL power calculation. First, more individual IOL power calculation is possible, for example in eyes with irregular cornea or those eyes who have previously undergone refractive surgery. Second, because it is a purely physical approach, no empirical ‘optimisation’ is required,” said Dr Hirnschall, referring to formula adjustments required for each surgeon. He presented the results of a study comparing the spherical equivalent outcomes of ray tracing-based IOL power calculation, using exact IOL design information, with the outcomes of a triple-optimised Haigis formula. The prospective study of 49 eyes of 49 patients used the IOLMaster 700 individualised eye model data, a physical lens position predictor and exact CT Asphina 409 MP IOL design information. “Ray tracing offers more detailed information of the cornea, as well as anatomical data instead of estimated lens position, both of which lead to a better refractive outcome,” said Dr Hirnschall. A potential limitation of the method is that exact IOL design information is needed Ray tracing resulted in a 2.5% increase in outcomes within 0.5D and 0.75D of target refraction, and a 10% increase in those coming within 1.00D. Prediction errors larger than 1.00D away from target refraction were lower in the ray tracing group (n=2) than in the Haigis group (n=13). “This shows promise not only for outcome performance, but also for surgeon and patient education, as well as management of patient expectations,” he concluded. Ray tracing involves calculating the path of a single “ray” of light passing through an optical system. In this case, retrospective ray tracing-based IOL power calculation was performed using retinal image quality metric (RIQM) criteria in an iterative procedure, and retinal image simulations were performed. In the ray tracing-based method, IOL selection is based on predicted visual acuity and a neuronal weighted RIQM. It involves ssOCT-based biometry and keratometry, using anterior and posterior corneal surfaces, corneal thickness, axial length, anterior chamber depth and white-to-white distance. Nino Hirnschall: nino.hirnschall@gmail.com
Latest Articles
Nutrition and the Eye: A Recipe for Success

A look at the evidence for tasty ways of lowering risks and improving ocular health.

Read more...

New Award to Encourage Research into Sustainable Practices

Read more...

Sharing a Vision for the Future

ESCRS leaders update Trieste conference on ESCRS initiatives.

Read more...

Extending Depth of Satisfaction

The ESCRS Eye Journal Club discuss a new study reviewing the causes and management of dissatisfaction after implantation of an EDOF IOL.

Read more...

Conventional Versus Laser-Assisted Cataract Surgery

Evidence favours conventional technique in most cases.

Read more...

AI Scribing and Telephone Management

Automating note-taking and call centres could boost practice efficiency.

Read more...

AI Analysis and the Cornea

A combination of better imaging and AI deep learning could significantly improve corneal imaging and diagnosis.

Read more...

Cooking a Feast for the Eyes

A cookbook to promote ocular health through thoughtful and traditional cuisine.

Read more...

Need to Know: Spherical Aberration

Part three of this series examines spherical aberration and its influence on higher-order aberrations.

Read more...

Generating AI’s Potential

How generative AI impacts medicine, society, and the environment.

Read more...