Cornea and IOP

Cornea and IOP
Cheryl Guttman Krader
Cheryl Guttman Krader
Published: Sunday, September 23, 2018
CORNEA characteristics can affect the accuracy of IOP measurements, but their influence also varies depending on the tonometry technology that is used, Jesper Hjortdal MD, PhD, told attendees at the 9th EuCornea Congress. Dr Hjortdal said that central corneal thickness has a large effect on Goldmann applanation, air-puff and rebound tonometry. The IOP reading obtained with these technologies may be artificially low in eyes with a thin cornea and overestimated if the cornea thickness is greater than the normal range, he explained. Dr Hjortdal noted that corneal curvature might also be predicted to affect IOP measurements considering that a steeper cornea would be more difficult to applanate or indent than a flatter cornea. Available studies, however, indicate that at least when using Goldmann applanation tonometry, corneal curvature appears to have a minimal effect on the IOP readings. Corneal stiffness would also be expected to influence corneal applanation, and in contrast to curvature, corneal stiffness has been shown to affect IOP readings. Dr Hjortdal noted that IOP will be underestimated in eyes with keratoconus and overestimated in eyes with conditions associated with increased corneal stiffness, including corneal scarring and mucopolysaccharidosis. Of the available devices for measuring IOP, digital contour tonometer readings are possibly least influenced by corneal factors, said Dr Hjortdal, Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. “However, this technology is cumbersome, time-consuming, and more expensive to use,” he concluded.
Latest Articles
Nutrition and the Eye: A Recipe for Success

A look at the evidence for tasty ways of lowering risks and improving ocular health.

Read more...

New Award to Encourage Research into Sustainable Practices

Read more...

Sharing a Vision for the Future

ESCRS leaders update Trieste conference on ESCRS initiatives.

Read more...

Extending Depth of Satisfaction

The ESCRS Eye Journal Club discuss a new study reviewing the causes and management of dissatisfaction after implantation of an EDOF IOL.

Read more...

Conventional Versus Laser-Assisted Cataract Surgery

Evidence favours conventional technique in most cases.

Read more...

AI Scribing and Telephone Management

Automating note-taking and call centres could boost practice efficiency.

Read more...

AI Analysis and the Cornea

A combination of better imaging and AI deep learning could significantly improve corneal imaging and diagnosis.

Read more...

Cooking a Feast for the Eyes

A cookbook to promote ocular health through thoughtful and traditional cuisine.

Read more...

Need to Know: Spherical Aberration

Part three of this series examines spherical aberration and its influence on higher-order aberrations.

Read more...

Generating AI’s Potential

How generative AI impacts medicine, society, and the environment.

Read more...