Barrett True K formula provides accurate results in post-refractive surgery patient

Barrett True K formula provides accurate results in post-refractive surgery patient
[caption id="attachment_7411" align="alignnone" width="750"] Valentijn SC Webers[/caption] The Barrett True K intraocular lens (IOL) calculation formula provided better results than the ORA intraoperative aberrometer (Alcon) in a patient who had previously undergone radial keratotomy (RK), said Valentijn SC Webers MD, in a case study he presented at Cornea Day at the 21st ESCRS Winter Meeting in Maastricht, The Netherlands. The patient, a 50-year-old man, had a very unusual eye. Apart from undergoing previous RK with five cuts for high myopia, he had an axial length of 30mm and a very flat K-reading of 30D. He presented with a progressive cataract that had reduced his visual acuity to a decimal value of 0.4, noted Dr Webers, of University Eye Clinic Maastricht, The Netherlands. Dr Webers and his associates opted to perform femtosecond laser-assisted cataract surgery and also perform intraoperative IOL calculation with the ORA device. Preoperative IOL calculations performed with the Barrett True K IOL calculation formula suggested using a 12.5D IOL, however intraoperative measurements suggested using a 14.5D IOL. In the end the Maastricht team compromised and implanted a 13.0D monofocal IOL, which, according to the ORA should have yielded a postoperative spherical equivalent refraction of 0.00D, but according to the Barrett True K formula would result in a postoperative refraction of -1.5D. They found that at one day postoperative the spherical equivalent was 0.25D, very close to that predicted by the ORA. However, by six weeks the spherical equivalent was 1.5D, exactly as predicted by the Barrett True K formula.
Latest Articles
ESCRS Today 2025: Happy Anniversaries!

ESCRS celebrates milestones with pioneers in IOLs, LASIK, femtosecond lasers, and corneal transplantation.

Read more...

ESCRS Today 2025: A Congress for Everyone

From YOs to families, the ESCRS Annual Meeting embraces full participation through inclusivity.

Read more...

ESCRS Today 2025: All Eyes on Innovation

Watching out for obstacles and opportunities

Read more...

Beyond the Numbers

Empowering patient participation fosters continuous innovation in cataract surgery.

Read more...

Thinking Beyond the Surgery Room

Practice management workshop focuses on financial operations and AI business applications.

Read more...

Aid Cuts Threaten Global Eye Care Progress

USAID closure leads retreat in development assistance.

Read more...

Supplement: ESCRS Clinical Trends Series: Presbyopia

Read more...

Debate: FS-LASIK or KLEx for Hyperopia?

FS-LASIK has more of a track record, but KLEx offers advantages.

Read more...

Four AI Applications Ready for Practice

Commercial offerings may save time, improve practice and research.

Read more...

Perioperative Medication Regimens for Cataract Surgery

Randomised controlled clinical trial results provide evidence-based guidance.

Read more...