New IOL: Results

New design provides 
moderate accommodation

New IOL: Results
Roibeard O’hEineachain
Roibeard O’hEineachain
Published: Monday, July 3, 2017
A new intraocular lens (IOL) with a different style hinged optic-haptic juncture from older accommodative IOLs appears to provide a moderate forward shift in response to pilocarpine-induced ciliary muscle contraction, but at the cost of increased posterior capsule opacification (PCO), according to a study presented at the 21st ESCRS Winter Meeting in Maastricht, The Netherlands, by Nino Hirnschall MD, PhD. The study included eight patients with a mean age of 69 years. All received the new accommodating IOL (ActaLens™, Emmetrope, designed by Andrew Phillips) in one eye and a control IOL, either the Crystalens® (Bausch + Lomb) or the AcrySof® IQ (Alcon) in the fellow eye, said Dr Hirnschall, Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital, Vienna, Austria. At 20 months’ follow-up, the researchers measured anterior chamber depth (ACD) with an optical biometry device (Lenstar, Haag-Streit AG, Switzerland) on two measurement days. On the first measurement day they determined ACD prior to instillation of topical pilocarpine and 30 minutes later. On the second measurement day, they followed the same procedure but used 1% cyclopentolate instead of pilocarpine. MODERATE ACCOMMODATION They found that pilocarpine reduced ACD by a mean of 0.32mm (p=0.014) in the ActaLens group compared to only 0.04mm in the control group (p=0.854). In addition, cyclopentolate increased ACD by 0.14mm in the ActaLens group (p=0.014), compared to only 0.03mm in the control group (p=0.181). A disadvantage of the new accommodating IOL was an increased level of PCO. Two independent examiners graded PCO, on a scale of 0 to 3, as 2.4 in the ActaLens group, compared to 1.8 in the Crystalens group and 0.l1 in the AcrySof group (p<0.001). In addition, Nd:YAG rates were higher in the study group, but the difference did not reach statistical significance. Dr Hirnschall noted that the ActaLens is a forward-vaulted plate silicone IOL with hinges between the haptic and the optic. It has a total length of 11mm and an optic diameter of 5.5mm. During production, the IOL is flattened with a vicryl suture. Patients undergo cycloplaegia during the first four weeks after surgery. Laser suturolysis performed six weeks after surgery allows the optic to move forward to its accommodating non-planar state during ciliary muscle contraction. “The investigated IOL is a novel concept for an accommodating IOL and results showed a moderate pilocarpine-induced forward shift of the IOL. However, the investigated IOL seems to have a higher PCO rate compared to standard monofocal IOLs,” he concluded. Nino Hirnschall: nino.hirnschall@gmail.com
Tags: IOL
Latest Articles
Organising for Success

Professional and personal goals drive practice ownership and operational choices.

Read more...

Update on Astigmatism Analysis

Read more...

Is Frugal Innovation Possible in Ophthalmology?

Improving access through financially and environmentally sustainable innovation.

Read more...

iNovation Innovators Den Boosts Eye Care Pioneers

New ideas and industry, colleague, and funding contacts among the benefits.

Read more...

From Concept to Clinic

Partnerships with academia and industry promote innovation.

Read more...

José Güell: Trends in Cornea Treatment

Endothelial damage, cellular treatments, human tissue, and infections are key concerns on the horizon.

Read more...

Making IOLs a More Personal Choice

Surgeons may prefer some IOLs for their patients, but what about for themselves?

Read more...

Need to Know: Higher-Order Aberrations and Polynomials

This first instalment in a tutorial series will discuss more on the measurement and clinical implications of HOAs.

Read more...

Never Go In Blind

Novel ophthalmic block simulator promises higher rates of confidence and competence in trainees.

Read more...

Simulators Benefit Surgeons and Patients

Helping young surgeons build confidence and expertise.

Read more...