Astigmatism measurement based on total corneal power


Cheryl Guttman Krader
Published: Tuesday, November 3, 2015
Corneal topographic astigmatism based on total corneal power (CorT total) provides an accurate and consistent measure of astigmatism, said Noel Alpins MD at the XXXIII Congress of the ESCRS in Barcelona, Spain.
CorT total is derived using individual data for anterior and posterior corneal power measurements. In 2012, Dr Alpins and colleagues reported that CorT anterior, a corneal power measure based on anterior corneal power measurements only, corresponded better with manifest refractive cylinder in both magnitude and orientation than simulated keratometry, corneal wavefront, manual keratometry, and automated keratometry (Alpins N et al. J Cataract Refract Surg. 2012;38(11):1978-88).
Now, a study evaluating the performance of CorT total showed that it corresponded better with manifest refractive cylinder, both in variability and closeness, than CorT anterior and consequently the other measures also.
“Accuracy for the total astigmatic power of the cornea and its meridian is of utmost importance when correcting astigmatism, and CorT gives more accurate information than other parameters because it is derived from all measured data rather than from only a limited area of the cornea,” said Dr Alpins, Medical Director, NewVision Clinics, Melbourne, Australia. (see Figure 1)
“Therefore, when planning toric intraocular lens selection and orientation, or the length and orientation of limbal relaxing incisions, we believe cataract surgeons should use the CorT parameter, total or anterior depending on whether their tomography/topography system measures the posterior and anterior cornea or just the anterior surface,” he added.
The study comparing the performance of CorT total and CorT anterior has also been published (Alpins N et al. J Refract Surg. 2015;31(3):182-6). It included data from 526 surgically-naïve eyes of patients presenting for laser vision correction.
Corneal power measurements obtained with the Sirius tomographer (Costruzione Strumenti Oftalmici) were used to determine total and CorT anterior values for each eye. Correspondence of the CorT values with refractive cylinder was analysed based on calculations for ocular residual astigmatism (ORA) mean magnitude and standard deviation. ORA is the vectorial difference between the corneal astigmatism and the refractive cylinder at the corneal plane. (see Figure 2)
Compared with CorT anterior, CorT total had significantly lower values for both mean ORA magnitude (0.30 vs 0.32D) and ORA variability (SD 0.53 vs 0.64D), that is the CorT total was closer to the manifest refractive cylinder than CorT anterior. (see Figure 3)
“A lower mean ORA magnitude indicates closer correlation between refractive cylinder and corneal astigmatism, and a lower standard deviation indicates lower variability,” Dr Alpins explained.
CorT total is now available on these tomography platforms that measure total corneal power – CSO Sirius, Pentacam (Oculus), and Galilei (Ziemer). Those three systems, as well as the Atlas (Carl Zeiss Meditec) and OPD-Scan III (Nidek), have the capability of providing CorT anterior. The iAssort software is required for calculation of the CorT parameter (www.assort.com).
Noel Alpins: alpins@newvisionclinics.com.au
Tags: cornea
Latest Articles
Simulators Benefit Surgeons and Patients
Helping young surgeons build confidence and expertise.
How Many Surgeries Equal Surgical Proficiency?
Internet, labs, simulators, and assisting surgery all contribute.
Improving Clinical Management for nAMD and DME
Global survey data identify barriers and opportunities.
Are Postoperative Topical Antibiotic Drops Still Needed?
Cataract surgeons debate the benefits of intracameral cefuroxime prophylaxis.
Emerging Technology for Detecting Subclinical Keratoconus
Brillouin microscopy shows promise in clinical studies.
Knowing Iris Repair: Modified Trifold Technique
Part eight of our series covers the modified trifold technique for large iris defects.
It’s All About Biomechanics!
Increasing the pool of patients eligible for refractive surgery.
Uncovering More Safe and Quick Options
Different strategies, such as PresbyLASIK, can offer presbyopes good outcomes.
Topography-Guided PRK for Keratoconus
Improving visual acuity in patients with keratoconus.
Defining AMD Treatment Protocol
Treatments trending to fewer injections for better results.